If your evaporative cooler hasn’t run since March, give it a check before the first 40-degree day, not after. Most summer breakdowns start with problems that were sitting there all winter.

Over the cooler months, pads dry out and collect dust and salt, water sits in the tank, float valves stick and pump seals harden. None of it shows until you switch the cooler on during the first heatwave and get warm, musty air, a dripping ceiling or nothing at all. By then, every evaporative air conditioning technician in Adelaide is booked out.

This guide explains what you can safely check yourself from the ground, how the pads and tank should be cleaned, how much water a cooler uses, the signs it needs a professional, what a service includes and what it costs, so your cooler is ready before summer arrives.

Why a Pre-Summer Check Matters in Adelaide

An evaporative cooler works by drawing hot outside air through wet pads. As the water evaporates, it cools the air, and a fan pushes that cooled air through the ducts into your home. It only works well when the pads are clean and evenly wet, the pump is moving water, the float valve is keeping the tank topped up, and the fan is turning freely.

Adelaide’s long, dry summers mean a cooler can run for hours every day for months, then sit idle for half the year. That stop-start pattern is hard on the parts:

  • Pads build up dust, scale and salt from evaporated water, which blocks airflow and leaves dry patches that don’t cool.
  • Water left in the tank over winter can go stale and corrode the tank and parts.
  • Float valves and drain valves can stick after months without use, causing leaks or a tank that won’t fill.
  • Pumps and motors can seize, and belts can crack or slip.
  • Birds, leaves and debris can get into the unit on the roof.

Regular servicing also makes a big difference to how long a cooler lasts. A well-serviced system typically lasts 15 to 20 years, while one that’s never serviced often fails at 8 to 10.

What You Can Safely Check Yourself

You can do a useful check without going near the roof. Pick a mild day, before the hot weather arrives, and work through these steps:

  1. Open some windows or doors. An evaporative cooler pushes air into the house, so it needs somewhere to escape. A closed-up house gets humid, and the cooler can’t do its job.
  2. Check the controller. Turn it on and look for any error code on the screen. Note it down if you see one; it tells a technician where to start.
  3. Run the fan only for a few minutes. Listen for grinding, squealing or rattling, and notice any musty or stale smell coming from the outlets.
  4. Switch to cooling and run it for 15 minutes. The air should feel noticeably cooler after a few minutes, and it should come evenly from every outlet.
  5. Check the ceilings. Look for new water stains or damp patches near the outlets and around the ceiling below the unit.
  6. Clean the ceiling outlets. Wipe or vacuum the grilles, and make sure any outlet dampers you close in winter are open again.
  7. Look at the roof from the ground. Water running constantly down the roof, into the gutter or out of the drain hose while the cooler is off is a sign of a valve fault.

If everything passes, your cooler is in reasonable shape. If anything smells, leaks, sounds wrong or doesn’t cool, book a service before the weather turns.

Stay Off the Roof

Evaporative coolers sit on the roof, and the manufacturers themselves warn that climbing onto a roof can be hazardous. The pads, tank, pump and power isolating switch are all inside the unit. Removing a winter cover, taking out pad frames or cleaning the tank means working at height next to water and electricity. That’s a job for a technician with the right access equipment.

How the Pads and Tank Should Be Cleaned

Pad and tank cleaning is part of a proper start-of-season service. Manufacturer guidance for common Australian units sets out the steps:

  • Power is isolated first, at the isolating switch inside the cooler.
  • Pad frames are removed and the pads gently washed to remove dust. High-pressure water should never be used on the pads, as it damages them.
  • Salt-crusted pads are replaced. Once pads are heavily scaled, washing won’t bring back their cooling.
  • The tank is drained and cleaned, along with the pump filter and any salinity probe.
  • The water channels that spread water over the pads are cleared so the pads are wet evenly.
  • Pads are refitted in the right positions, because some models use different pads in different places. Fitting them wrongly can let water bypass the pads or affect the float valve.
  • The float valve, drain valve and leaks are checked, then the cooler is run and tested.

If you’re confident working at height and want to do this yourself, follow your cooler’s owner manual exactly. For most people, it’s safer and quicker to have it done as part of a service.

Want your cooler ready before the first heatwave?

Call 0484 600 095. Our dual-licensed technicians service, clean and repair evaporative coolers across Adelaide, with safe roof access and one visit for both the plumbing and electrical side.

Upfront pricing before we start · All major brands · All Adelaide metro suburbs

How Much Water Does an Evaporative Cooler Use?

More than most people expect. Water Corporation in Western Australia estimates that around 100 litres an hour can evaporate from the pads in hot weather, which adds up to 30,000 litres or more a year based on six hours a day for 50 days. Adelaide’s summers are similar, so it’s a fair guide here too.

On top of evaporation, coolers drain off some water while they run, either through a constant bleed or by dumping the tank from time to time. This flushes out the salts that build up as water evaporates. Water Corporation suggests a bleed rate of 11 to 20 litres an hour depending on the system, and says some newer units bleed as little as 3 litres an hour.

Ways to keep water use down:

  • Have the bleed rate checked and set as part of a service. Too high wastes water; too low lets salt build up on the pads.
  • Fix a sticking float valve quickly. Water Corporation compares it to a running toilet, but out of sight on the roof.
  • Use the fan only in the cooler parts of the day and on humid days, when evaporation does little.
  • Turn the cooler off at night when you don’t need it, and when you go away.

Signs Your Cooler Needs a Professional Service

  • Musty, stale or damp smells from the outlets.
  • Weak airflow, or air that isn’t much cooler than outside.
  • Dry or patchy pads, which usually means a pump, water distribution or float valve problem.
  • Water leaking into the ceiling, around outlets or down the walls. Here’s what causes an evaporative cooler to leak water inside.
  • Water running constantly from the drain or down the roof.
  • A motor that hums but doesn’t spin, or grinding and squealing from the fan.
  • Error codes on the controller. On Bonaire units, common codes include E1 (water inlet), E2 (pump), E3 (temperature sensor) and E9 (controller communication).
  • White crust on the pads or the outside of the unit, which shows salt build-up.
  • It hasn’t been serviced for more than a year.

What a Professional Service Includes

A full start-of-season service from Wills Plumbing covers:

Part What we check
Cooling pads Condition and scale; cleaned or replaced
Sump (tank) and drain valve Drained and cleaned; checked for corrosion, sediment and sealing
Water pump Flow, noise and seal wear
Water inlet and float valve Leaks, pressure and correct water level
Water distribution Lines and channels cleared so the pads are wet evenly
Fan motor and belt Bearings, belt tension and running current
Controller and wiring Operation and error codes
Ducting and outlets Leaks, airflow and dampers
Roof mounting and flashings Secure mounting and weatherproofing
Test run Full run and airflow check

An annual service typically costs $220 to $380, depending on the size, brand and condition of the unit, with replacement pads extra if they’re needed. At the end of summer, a winter shutdown, which drains the system, isolates the water and protects the pads, typically costs $180 to $280.

Repair or Replace?

If the check or service finds a fault, most are fixed on the spot. As a guide, these are typical repair costs from our Adelaide price guide:

Fault Typical cost
Not cooling or low water in the tank (cooler under 8 years old) $220 to $450
Dry or patchy pads (cooler under 8 years old) $300 to $600
Controller failure $380 to $650
Motor humming but not spinning (8 to 15 years old) $550 to $900
Corroded pad frame $600 to $1,200
Water leaking into the ceiling Quoted after inspection
Multiple or major faults in an older cooler: replacement $2,800 to $4,500

A cooler more than 15 years old with several faults is usually better replaced than repaired. A newer unit with one failed part is usually worth fixing. We’ll tell you honestly which makes sense for yours.

Adelaide plumber from Wills Plumbing Adelaide getting tools from van

Brands We Service

We service and repair all the evaporative brands common in Adelaide homes, including Breezair, Bonaire, Braemar, Coolair, Seeley, Celair and Brivis. If you’re not sure what brand you have, the name is usually on the unit or the wall controller, and a photo of the controller helps us bring the right parts.

Book Before the Rush

The best time to service an evaporative cooler is in winter or early spring, before the hot weather. Once the first heatwave hits, demand jumps and waiting times stretch out. If yours isn’t serviced yet, book as early as you can, rather than waiting until it fails on a hot day.

Book your evaporative cooler service.

Wills Plumbing services, repairs and replaces evaporative coolers across Adelaide. We set up safe roof access, clean and check every part, and give you an upfront price for any repair before we start.

Same-day service available · Upfront pricing before we start · Plumbing and electrical in one visit

Call 0484 600 095 or book an evaporative cooler service.

Frequently Asked Questions

How often should an evaporative cooler be serviced?

Once a year before summer is the usual recommendation for Adelaide homes. Some manufacturers set their own maintenance schedule, so check your owner’s manual, and service more often if the cooler runs heavily or the water is hard.

Can I clean my evaporative cooler pads myself?

The pads are inside the unit on the roof, so cleaning them means working at height near water and electricity. If you do it, isolate the power first, wash the pads gently and never use high-pressure water. For most people, it’s safer to have it done as part of a service.

Why does my evaporative cooler smell musty?

Usually because of stale water left in the tank over winter, or dirty or scaled pads. Draining and cleaning the tank and cleaning or replacing the pads normally fixes it.

How much does an evaporative cooler service cost in Adelaide?

Typically $220 to $380, depending on the size, brand and condition of the unit. Replacement pads are extra if they’re needed.

How much water does an evaporative cooler use?

Water Corporation estimates around 100 litres an hour can evaporate in hot weather, plus water bled off to control salt. A service sets the bleed rate so the cooler doesn’t waste water.

Why is my evaporative cooler blowing warm air?

Common causes are dry or patchy pads from a pump, float valve or water distribution fault, scaled pads, or a drain valve that isn’t closing so the tank can’t fill. A technician can find the cause quickly.

Do I need a winter shutdown?

It’s worth doing. A winter shutdown drains the system, isolates the water and protects the pads, which helps prevent corrosion, stale water and cold drafts. It typically costs $180 to $280.

A Cool Summer Starts in Spring

Run a quick check from the ground on a mild day, keep off the roof, and book a service if anything smells, leaks, sounds wrong or doesn’t cool. A serviced cooler uses less water, lasts longer and is far less likely to fail on the hottest day of the year. To book, call Wills Plumbing on 0484 600 095.